List of generated methods in project: Analyzer

This text description is generated by Processor Expert. Do not modify it.
=============================================================================

Module "PWM1"      (component PWM)
   - PWM1_Enable -This method enables the component - it starts the signal generation. Events may be generated 
                (<DisableEvent>/<EnableEvent>).
   - PWM1_Disable -This method disables the component - it stops the signal generation and events calling. When the timer is 
                disabled, it is possible to call <ClrValue> and <SetValue> methods.
   - PWM1_SetRatio8 -This method sets a new duty-cycle ratio. Ratio is expressed as an 8-bit unsigned integer number. 0 - FF 
                value is proportional to ratio 0 - 100%. The method is available only if it is not selected list of predefined 
                values in <Starting pulse width> property.   Note: Calculated duty depends on the timer capabilities and on the 
                selected period.
   - PWM1_SetRatio16 -This method sets a new duty-cycle ratio. Ratio is expressed as a 16-bit unsigned integer number. 0 - FFFF 
                value is proportional to ratio 0 - 100%. The method is available only if it is not selected list of predefined 
                values in <Starting pulse width> property.   Note: Calculated duty depends on the timer possibilities and on 
                the selected period.
   - PWM1_SetDutyUS -This method sets the new duty value of the output signal. The duty is expressed in microseconds as a 
                16-bit unsigned integer number. The method is available only if it is not selected list of predefined values in 
                <Starting pulse width> property.

Module "TU1"       (component TimerUnit_LDD)
   - TU1_Init -Initializes the device. Allocates memory for the device data structure, allocates interrupt vectors and sets 
                interrupt priority, sets pin routing, sets timing, etc. If the property <"Enable in init. code"> is set to 
                "yes" value then the device is also enabled (see the description of the <Enable> method). In this case the 
                <Enable> method is not necessary and needn't to be generated. This method can be called only once. Before the 
                second call of Init the <Deinit> must be called first.
   - TU1_Enable -Enables the component - it starts the signal generation. Events may be generated (see SetEventMask). The 
                method is not available if the counter can't be disabled/enabled by HW.
   - TU1_Disable -Disables the component - it stops signal generation and events calling. The method is not available if the 
                counter can't be disabled/enabled by HW.
   - TU1_GetPeriodTicks -Returns the number of counter ticks before re-initialization. See also method <SetPeriodTicks>. This 
                method is available only if the property <"Counter restart"> is switched to 'on-match' value.
   - TU1_ResetCounter -Resets counter. If counter is counting up then it is set to zero. If counter is counting down then 
                counter is updated to the reload value.   The method is not available if HW doesn't allow resetting of the 
                counter.
   - TU1_GetCounterValue -Returns the content of counter register. This method can be used both if counter is enabled and if 
                counter is disabled. The method is not available if HW doesn't allow reading of the counter.
   - TU1_SetOffsetTicks -Sets the new offset value to channel specified by the parameter ChannelIdx. It is user responsibility 
                to use value below selected period. This method is available when at least one channel is configured.
   - TU1_GetOffsetTicks -Returns the number of counter ticks to compare match channel specified by the parameter ChannelIdx. 
                See also method <SetOffsetTicks>. This method is available when at least one channel is configured.
   - TU1_SelectOutputAction -Sets the type of compare match and counter overflow action on channel output. This method is 
                available when at least one channel is configured.

Module "PWM2"      (component PWM)
   - PWM2_Enable -This method enables the component - it starts the signal generation. Events may be generated 
                (<DisableEvent>/<EnableEvent>).
   - PWM2_Disable -This method disables the component - it stops the signal generation and events calling. When the timer is 
                disabled, it is possible to call <ClrValue> and <SetValue> methods.
   - PWM2_SetRatio8 -This method sets a new duty-cycle ratio. Ratio is expressed as an 8-bit unsigned integer number. 0 - FF 
                value is proportional to ratio 0 - 100%. The method is available only if it is not selected list of predefined 
                values in <Starting pulse width> property.   Note: Calculated duty depends on the timer capabilities and on the 
                selected period.
   - PWM2_SetRatio16 -This method sets a new duty-cycle ratio. Ratio is expressed as a 16-bit unsigned integer number. 0 - FFFF 
                value is proportional to ratio 0 - 100%. The method is available only if it is not selected list of predefined 
                values in <Starting pulse width> property.   Note: Calculated duty depends on the timer possibilities and on 
                the selected period.
   - PWM2_SetDutyUS -This method sets the new duty value of the output signal. The duty is expressed in microseconds as a 
                16-bit unsigned integer number. The method is available only if it is not selected list of predefined values in 
                <Starting pulse width> property.

Module "TU2"       (component TimerUnit_LDD)
   - TU2_Init -Initializes the device. Allocates memory for the device data structure, allocates interrupt vectors and sets 
                interrupt priority, sets pin routing, sets timing, etc. If the property <"Enable in init. code"> is set to 
                "yes" value then the device is also enabled (see the description of the <Enable> method). In this case the 
                <Enable> method is not necessary and needn't to be generated. This method can be called only once. Before the 
                second call of Init the <Deinit> must be called first.
   - TU2_Enable -Enables the component - it starts the signal generation. Events may be generated (see SetEventMask). The 
                method is not available if the counter can't be disabled/enabled by HW.
   - TU2_Disable -Disables the component - it stops signal generation and events calling. The method is not available if the 
                counter can't be disabled/enabled by HW.
   - TU2_GetPeriodTicks -Returns the number of counter ticks before re-initialization. See also method <SetPeriodTicks>. This 
                method is available only if the property <"Counter restart"> is switched to 'on-match' value.
   - TU2_ResetCounter -Resets counter. If counter is counting up then it is set to zero. If counter is counting down then 
                counter is updated to the reload value.   The method is not available if HW doesn't allow resetting of the 
                counter.
   - TU2_GetCounterValue -Returns the content of counter register. This method can be used both if counter is enabled and if 
                counter is disabled. The method is not available if HW doesn't allow reading of the counter.
   - TU2_SetOffsetTicks -Sets the new offset value to channel specified by the parameter ChannelIdx. It is user responsibility 
                to use value below selected period. This method is available when at least one channel is configured.
   - TU2_GetOffsetTicks -Returns the number of counter ticks to compare match channel specified by the parameter ChannelIdx. 
                See also method <SetOffsetTicks>. This method is available when at least one channel is configured.
   - TU2_SelectOutputAction -Sets the type of compare match and counter overflow action on channel output. This method is 
                available when at least one channel is configured.

Module "AD1"       (component ADC)
   - AD1_Measure -This method performs one measurement on all channels that are set in the component inspector. (Note: If the 
                <number of conversions> is more than one the conversion of A/D channels is performed specified number of times.)
   - AD1_MeasureChan -This method performs measurement on one channel. (Note: If the <number of conversions> is more than one 
                the conversion of the A/D channel is performed specified number of times.)
   - AD1_GetValue16 -This method returns the last measured values of all channels. Compared with <GetValue> method this method 
                returns more accurate result if the <number of conversions> is greater than 1 and <AD resolution> is less than 
                16 bits. In addition, the user code dependency on <AD resolution> is eliminated.
   - AD1_GetChanValue16 -This method returns the last measured value of the required channel. Compared with <GetChanValue> 
                method this method returns more accurate result if the <number of conversions> is greater than 1 and <AD 
                resolution> is less than 16 bits. In addition, the user code dependency on <AD resolution> is eliminated.
   - AD1_Calibrate -This method starts self calibration process. Calibration is typically used to remove the effects of the 
                gain and offset from a specific reading.

Module "AS1"       (component AsynchroSerial)
   - AS1_RecvChar -If any data is received, this method returns one character, otherwise it returns an error code (it does not 
                wait for data). This method is enabled only if the receiver property is enabled.  [Note:] Because the preferred 
                method to handle error and break exception in the interrupt mode is to use events <OnError> and <OnBreak> the 
                return value ERR_RXEMPTY has higher priority than other error codes. As a consequence the information about an 
                exception in interrupt mode is returned only if there is a valid character ready to be read.
   - AS1_SendChar -Sends one character to the channel. If the component is temporarily disabled (Disable method) SendChar 
                method only stores data into an output buffer. In case of a zero output buffer size, only one character can be 
                stored. Enabling the component (Enable method) starts the transmission of the stored data. This method is 
                available only if the transmitter property is enabled.
   - AS1_SendBlock -Sends a block of characters to the channel.  This method is available only if non-zero length of the output 
                buffer is defined and the transmitter property is enabled.
   - AS1_ClearTxBuf -Clears the transmit buffer.  This method is available only if non-zero length of the output buffer is 
                defined and the receiver property is enabled.
   - AS1_GetCharsInRxBuf -Returns the number of characters in the input buffer. This method is available only if the receiver 
                property is enabled.
   - AS1_GetCharsInTxBuf -Returns the number of characters in the output buffer. This method is available only if the 
                transmitter property is enabled.

Module "Cpu"       (component MKL25Z128LK4)

===================================================================================